Save Using Boiler Sequencer Pro Controller Modules
- Designed for Lo/Hi/On/Off Boilers/Chillers
- Designed for fully modulating Boilers
How many times have you said “If only I had a sequence
device that worked the way it needs to at a sensible price”….well
now you have! A single device that can automatically sequence
and rotate up to 5 Lo/Hi flame boilers from a single 0-10v
input! Or a single device that can sequence up to 4 modulating
boilers from a single control signal.
Boiler Pro-10 can sequence up to 10 boilers, or it can sequence
5 Lo stages followed by 5 Hi flame stages and still rotate
the lead load!. Boiler Pro-4 will control up to 4 boilers
or 2 Lo/Hi Boilers with the same options.
Boiler
Pro-4A can sequence up to 4 modulating boilers and has
built-in relays for enabling / disabling the corresponding
boiler at each stage.
Each Boiler Pro will automatically rotate boilers. It can
do this whenever there is no system demand.
The demand-based rotation provides even better load sharing
of the lead load than most BMS installations are ever programmed
to provide.
Using the Boiler Pro will reduce the DO/AO of any BMS controller
and the associated engineering times creating very significant
cost savings for all boiler associated projects.
Note: Boiler Pro modules are compatible
with any BMS Controller / Outstation!
- Boiler Sequencer Pro for up to 10 Traditional Boilers
- Boiler Sequencer Pro Analogue version for up to 4 Modulating Boilers
- Simple Installation
- Automatic Lead Boiler Rotation
- Compatible with any BMS Controller
The boiler pro also works seamlessly with our
HRP22 controller with built in user interface, web connectivity
or GSM/Autodial interrogation options that make it ideal for
any project where user simplicity is a key requirement.
Boiler Sequencer Pro On/Off/Hi/Lo Model
- One 0-10v Signal controls up to 10 Boilers
- Various control options …Lo/Hi/Lo/Hi, Lo/Lo/Hi/Hi
- Automated lead boiler rotation of all load types
Boiler Sequencer Pro Analogue Model
- One 0-10V Signal controls up to 4 x 0-10Vdc Modulating Boilers
- Additional relay outputs available for each stage to enable the boilers, if the enable signal is required
- Automatic lead boiler rotation based on demand
Most outstations and controllers have relatively few analogue
outputs. Additional 0-10Vdc outputs require either upgrade
on the outstation/controller size, or purchase of additional
I/O-modules. Furthermore programming analogue sequencing
with lead boiler rotation is a time consuming task. The
BPRO-4A analogue boiler sequencer is designed to provide
significant savings on the outstation programming and I/O-requirements.
| MODEL |
DESCRIPTION |
SEQUENCING |
LEAD BOILER ROTATION |
| BPRO-4 |
Boiler Sequencer Pro for Up to 4 Boilers / Chillers |
Automatic for 3 or 4 Boilers |
Yes |
| BPRO-10 |
Boiler Sequencer Pro for Up to 10 Boilers / Chillers |
Automatic for up to 10 Boilers |
Yes |
| BPRO-4A |
Analogue Boiler Sequencer for up to 4 Fully Modulating
Boilers |
Automatic for up to 4 0.10V boilers |
Yes |
The Boiler Pro-10, Boiler Pro-4, Boiler Pro-4A and HRP22 are
only available from www.syxthsense.com,
the UK’s fastest growing control solution provider.